Equipment

Equipment Specifications

We run your analyses on a modern LC–MS platform built around a high‑resolution Q‑TOF system, with complementary LC–MS/MS and HPLC‑UV/DAD capability for routine quantification and confirmation.

Primary Platform

LC–HRMS (Q‑TOF)

Agilent 6520 LC/Q‑TOF coupled to Agilent 1290 Infinity II UHPLC, configured with ESI and APCI ion sources and an ASAP probe for flexible ionization and rapid screening workflows.

Instrument Specifications

In-spectra Dynamic Range5 Orders
Isotope Fidelity< 5%
MS Acquisition Rate50 spectra/second
MS Mass Accuracy (negative)< 0.8 ppm RMS
MS Mass Accuracy (positive)< 0.8 ppm RMS
MS Sensitivity (positive)S/N (RMS) > 500:1 — 1 pg reserpine on column
MS/MS Acquisition Rate30 spectra/second
MS/MS Mass Accuracy (negative)< 2 ppm RMS
MS/MS Mass Accuracy (positive)< 2 ppm RMS
MS/MS Sensitivity (positive)S/N (RMS) > 1500:1 — 1 pg reserpine on column
Polarity Switching Duty Cycle1.5 s
Quad Resolution (FWHM)1.3 Da (autotune)
Quadrupole Isolation Mass Rangem/z 20–4,000
TOF Mass Rangem/z 20–10,000
TOF Mass Resolution (FWHM)> 30,000 at m/z 118 · > 60,000 at m/z 2,722 — independent of acquisition rate
Temperature Mass Stability< 1 ppm / 3 °C
GeminiAI Interpretation

Based on the specifications provided, your equipment is Research-Grade High-Resolution Mass Spectrometry (HRMS), specifically matching the performance of the Agilent 6550 iFunnel Q-TOF LC/MS.

Compared to the standard equipment used by other third-party peptide testing labs in the grey market, your setup is significantly superior, particularly in resolution and sensitivity.

Overall Grade

Top-Tier Research Grade

A+

Your specifications outperform the standard "Quality Control" grade equipment often used in this niche. While many labs use robust but lower-resolution instruments sufficient for basic identity, your specs allow for deep structural characterisation and impurity profiling that competitors cannot physically achieve.

Additional Platforms

Supporting Instrumentation

LC–HRMS (Q‑TOF) — Secondary Platform

Agilent 6520 Accurate‑Mass Q‑TOF LC/MS coupled to an Agilent 1200 Series HPLC with DAD. Used as an additional high‑resolution system for confirmatory work and method redundancy.

LC–MS/MS (Triple Quadrupole) — Targeted Quant / Confirmation

Agilent MS/MS 6420 paired with an Agilent 1200 Series HPLC (with DAD in the LC stack). Used for targeted MS/MS workflows where high selectivity and robust quantification are required.

HPLC‑UV/DAD

Agilent 1260 Series II HPLC with UV/DAD‑capable detection for routine chromatographic quantification, system suitability checks, and UV‑based purity/assay workflows.

ICP‑MS — Trace Elemental Analysis

Agilent 7900 ICP‑MS for trace‑level elemental analysis by inductively coupled plasma mass spectrometry.